Sledovat
Geert J. Streekstra
Geert J. Streekstra
Neznámá organizace
E-mailová adresa ověřena na: andrew.cmu.edu
Název
Citace
Citace
Rok
Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis
JGG Dobbe, GJ Streekstra, B Atasever, R Van Zijderveld, C Ince
Medical & biological engineering & computing 46, 659-670, 2008
3062008
Fibrin network structure and clot mechanical properties are altered by incorporation of erythrocytes
KC Gersh, C Nagaswami, JW Weisel
Thrombosis and haemostasis 102 (12), 1169-1175, 2009
3042009
A new method to study shape recovery of red blood cells using multiple optical trapping
PJ Bronkhorst, GJ Streekstra, J Grimbergen, EJ Nijhof, JJ Sixma, ...
Biophysical journal 69 (5), 1666-1673, 1995
2011995
CT image segmentation methods for bone used in medical additive manufacturing
M Van Eijnatten, R van Dijk, J Dobbe, G Streekstra, J Koivisto, J Wolff
Medical engineering & physics 51, 6-16, 2018
1932018
Measurement of the distribution of red blood cell deformability using an automated rheoscope
JGG Dobbe, GJ Streekstra, MR Hardeman, C Ince, CA Grimbergen
Cytometry: The Journal of the International Society for Analytical Cytology …, 2002
1502002
Light scattering by red blood cells in ektacytometry: Fraunhofer versus anomalous diffraction
GJ Streekstra, AG Hoekstra, EJ Nijhof, RM Heethaar
Applied Optics 32 (13), 2266-2272, 1993
1361993
Metal artifact reduction techniques in musculoskeletal CT-imaging
RHH Wellenberg, ET Hakvoort, CH Slump, MF Boomsma, M Maas, ...
European journal of radiology 107, 60-69, 2018
1342018
Analyzing red blood cell-deformability distributions
JGG Dobbe, MR Hardeman, GJ Streekstra, J Strackee, C Ince, ...
Blood Cells, Molecules, and Diseases 28 (3), 373-384, 2002
1202002
Visualisation of intramural coronary vasculature by an imaging cryomicrotome suggests compartmentalisation of myocardial perfusion areas
JAE Spaan, R ter Wee, JWGE van Teeffelen, G Streekstra, M Siebes, ...
Medical and Biological Engineering and Computing 43, 431-435, 2005
1182005
Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses
RHH Wellenberg, MF Boomsma, JAC van Osch, A Vlassenbroek, J Milles, ...
European journal of radiology 88, 61-70, 2017
972017
Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre-and intraoperative imaging
JGG Dobbe, SD Strackee, AW Schreurs, R Jonges, B Carelsen, ...
IEEE transactions on biomedical engineering 58 (1), 182-190, 2010
932010
Computer-assisted and patient-specific 3-D planning and evaluation of a single-cut rotational osteotomy for complex long-bone deformities
JGG Dobbe, KJ Du Pré, P Kloen, L Blankevoort, GJ Streekstra
Medical & biological engineering & computing 49, 1363-1370, 2011
812011
Differences in CT perfusion summary maps for patients with acute ischemic stroke generated by 2 software packages
F Fahmi, HA Marquering, GJ Streekstra, LFM Beenen, BK Velthuis, ...
American Journal of Neuroradiology 33 (11), 2074-2080, 2012
742012
Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination: Removal of bone in CT angiography
M Van Straten, HW Venema, GJ Streekstra, CBLM Majoie, GJ den Heeten, ...
Medical physics 31 (10), 2924-2933, 2004
712004
Enhancement of red blood cell transfusion compatibility using CRISPR‐mediated erythroblast gene editing
J Hawksworth, TJ Satchwell, M Meinders, DE Daniels, F Regan, ...
EMBO molecular medicine 10 (6), e8454, 2018
692018
Quantification of the fraction poorly deformable red blood cells using ektacytometry
GJ Streekstra, JGG Dobbe, AG Hoekstra
Optics express 18 (13), 14173-14182, 2010
682010
Statistical descriptions of scaphoid and lunate bone shapes
M van de Giessen, M Foumani, GJ Streekstra, SD Strackee, M Maas, ...
Journal of biomechanics 43 (8), 1463-1469, 2010
662010
Anomalous diffraction by arbitrarily oriented ellipsoids: applications in ektacytometry
GJ Streekstra, AG Hoekstra, RM Heethaar
Applied optics 33 (31), 7288-7296, 1994
661994
In-vivo three-dimensional carpal bone kinematics during flexion–extension and radio–ulnar deviation of the wrist: Dynamic motion versus step-wise static wrist positions
M Foumani, SD Strackee, R Jonges, L Blankevoort, AH Zwinderman, ...
Journal of biomechanics 42 (16), 2664-2671, 2009
652009
Three-dimensional assessment of bilateral symmetry of the radius and ulna for planning corrective surgeries
JC Vroemen, JGG Dobbe, R Jonges, SD Strackee, GJ Streekstra
The Journal of hand surgery 37 (5), 982-988, 2012
632012
Systém momentálně nemůže danou operaci provést. Zkuste to znovu později.
Články 1–20