Follow
Dr. Kaushik Sanyal
Dr. Kaushik Sanyal
Scientific officer , Bhabha Atomic Research Centre
Verified email at barc.gov.in - Homepage
Title
Cited by
Cited by
Year
Photoluminescence and EPR studies on Fe 3+ doped ZnAl 2 O 4: an evidence for local site swapping of Fe 3+ and formation of inverse and normal phase
N Pathak, SK Gupta, K Sanyal, M Kumar, RM Kadam, V Natarajan
Dalton Transactions 43 (24), 9313-9323, 2014
1172014
Luminescence of undoped and Eu 3+ doped nanocrystalline SrWO 4 scheelite: time resolved fluorescence complimented by DFT and positron annihilation spectroscopic studies
SK Gupta, K Sudarshan, PS Ghosh, K Sanyal, AP Srivastava, A Arya, ...
RSC advances 6 (5), 3792-3805, 2016
652016
Direct determination of oxidation states of uranium in mixed-valent uranium oxides using total reflection X-ray fluorescence X-ray absorption near-edge spectroscopy
K Sanyal, A Khooha, G Das, MK Tiwari, NL Misra
Analytical chemistry 89 (1), 871-876, 2017
612017
Selective micellar extraction of ultratrace levels of uranium in aqueous samples by task specific ionic liquid followed by its detection employing total reflection X-ray …
A Saha, K Sanyal, N Rawat, SB Deb, MK Saxena, BS Tomar
Analytical chemistry 89 (19), 10422-10430, 2017
402017
Improvements in energy dispersive X-ray fluorescence detection limits with thin specimens deposited on thin transparent adhesive tape supports
B Kanrar, K Sanyal, NL Misra, SK Aggarwal
Spectrochimica Acta Part B: Atomic Spectroscopy 101, 130-133, 2014
362014
Synthesis and uranium adsorption studies of UiO-66 (Ce) based metal organic frameworks from aqueous solutions
N Gumber, RV Pai, K Sanyal, B Dutta, PA Hassan
Microporous and Mesoporous Materials 341, 112108, 2022
202022
Arsenic quantification and speciation at trace levels in natural water samples by total reflection X-ray fluorescence after pre-concentration with N-methyl-d-glucamine …
K Sanyal, S Chappa, J Bahadur, AK Pandey, NL Mishra
Journal of Analytical Atomic Spectrometry 35 (11), 2770-2778, 2020
202020
Trace element determinations in uranium by Total reflection X-Ray Fluorescence spectrometry using a newly developed polymer resin for major matrix separation
K Sanyal, S Chappa, N Pathak, AK Pandey, NL Misra
Spectrochimica Acta Part B: Atomic Spectroscopy 150, 18-25, 2018
202018
A comparative study on the total reflection X‐ray fluorescence determination of low Z elements using X‐ray tube and synchrotron radiation as excitation sources
K Sanyal, B Kanrar, NL Misra, M Czyzycki, A Migliori, AG Karydas
X‐Ray Spectrometry 46 (3), 164-170, 2017
192017
Investigations on local structures in new Bi 2− 2x La 2x UO 6 (x= 0–0.05) solid solutions: a combined XRD, EXAFS, PL and EPR study
K Sanyal, N Pathak, AK Yadav, B Kanrar, RM Kadam, SN Jha, ...
Dalton Transactions 45 (18), 7650-7664, 2016
192016
Trace element determinations in uranium by energy dispersive X-ray fluorescence spectrometry using thin film specimens
K Sanyal, NL Misra
Spectrochimica Acta Part B: Atomic Spectroscopy 155, 44-49, 2019
152019
Drastic improvement in detection limits in energy dispersive X-ray fluorescence geometry utilizing micro-focused bremsstrahlung excitation in thin-film sample specimen
K Sanyal, B Kanrar, S Dhara
Journal of Analytical Atomic Spectrometry 36 (4), 803-812, 2021
122021
Direct multielemental trace determinations in plutonium samples by total reflection X-ray fluorescence spectrometry using a very small sample amount
K Sanyal, S Dhara, NL Misra
Analytical chemistry 90 (18), 11070-11077, 2018
122018
Results from a new low Z-high Z TXRF Spectrometer
K Sanyal, B Kanrar, S Dhara, NL Misra, P Wobrauschek, C Streli
Advances in X-ray Analysis, 125-143, 2015
112015
Application of TXRF for burn leach test of TRISO coated UO2 particles
K Sanyal, S Dhara, S Sanjay Kumar, NL Misra, PK Mollick, PT Rao, ...
Journal of Radioanalytical and Nuclear Chemistry 302, 1357-1361, 2014
112014
Determination of trace elements in normal and malignant breast tissues of different age group using total reflection X‐ray fluorescence spectrometer
S Mirji, NM Badiger, K Sanyal, SS Kulkarni, NL Misra, PB Gai
X‐Ray Spectrometry 47 (6), 432-440, 2018
102018
Quantification and distribution of trace elements in fusion bead and pressed pellet specimens using a table top micro-X-ray fluorescence spectrometer
B Kanrar, K Sanyal, S Dhara
Spectrochimica Acta Part B: Atomic Spectroscopy 177, 106063, 2021
82021
Direct determination of fluorine in high-purity water samples using vacuum sample chamber total reflection X-ray fluorescence spectrometry
K Sanyal, NL Misra
Journal of Analytical Atomic Spectrometry 33 (5), 876-882, 2018
82018
Improved approach for the determination of low‐Z elements in uranium samples using a vacuum chamber TXRF spectrometer
K Sanyal, S Dhara, NL Misra
X‐Ray Spectrometry 46 (5), 442-447, 2017
82017
A direct and safe method for plutonium determination using total reflection X-ray fluorescence spectrometry
S Dhara, K Sanyal, S Paul, NL Misra
Journal of Analytical Atomic Spectrometry 34 (2), 366-374, 2019
72019
The system can't perform the operation now. Try again later.
Articles 1–20