Follow
Hana Lísalová
Hana Lísalová
Other namesHana Vaisocherová, Hana Vaisocherová Lísalová
Vedoucí vědecký pracovník, Fyzikální ústav AV ČR
Verified email at fzu.cz - Homepage
Title
Cited by
Cited by
Year
Ultralow fouling and functionalizable surface chemistry based on a zwitterionic polymer enabling sensitive and specific protein detection in undiluted blood plasma
H Vaisocherova, W Yang, Z Zhang, Z Cao, G Cheng, M Piliarik, J Homola, ...
Analytical chemistry 80 (20), 7894-7901, 2008
4802008
Nonfouling behavior of polycarboxybetaine-grafted surfaces: structural and environmental effects
Z Zhang, H Vaisocherová, G Cheng, W Yang, H Xue, S Jiang
Biomacromolecules 9 (10), 2686-2692, 2008
3132008
Film thickness dependence of protein adsorption from blood serum and plasma onto poly (sulfobetaine)-grafted surfaces
W Yang, S Chen, G Cheng, H Vaisocherova, H Xue, W Li, J Zhang, ...
Langmuir 24 (17), 9211-9214, 2008
2752008
Multi-analyte surface plasmon resonance biosensing
J Homola, H Vaisocherová, J Dostálek, M Piliarik
Methods 37 (1), 26-36, 2005
2722005
Surface plasmon resonance biosensing
M Piliarik, H Vaisocherová, J Homola
Biosensors and Biodetection, 65-88, 2009
2632009
A new surface plasmon resonance sensor for high-throughput screening applications
M Piliarik, H Vaisocherová, J Homola
Biosensors and Bioelectronics 20 (10), 2104-2110, 2005
2342005
Low-fouling surface plasmon resonance biosensor for multi-step detection of foodborne bacterial pathogens in complex food samples
H Vaisocherová-Lísalová, I Víšová, ML Ermini, T Špringer, XC Song, ...
Biosensors and Bioelectronics 80, 84-90, 2016
2232016
Functionalizable surface platform with reduced nonspecific protein adsorption from full blood plasma—Material selection and protein immobilization optimization
H Vaisocherová, Z Zhang, W Yang, Z Cao, G Cheng, AD Taylor, M Piliarik, ...
Biosensors and Bioelectronics 24 (7), 1924-1930, 2009
2172009
Multichannel surface plasmon resonance biosensor with wavelength division multiplexing
J Dostálek, H Vaisocherová, J Homola
Sensors and Actuators B: Chemical 108 (1-2), 758-764, 2005
1722005
Functionalizable low-fouling coatings for label-free biosensing in complex biological media: advances and applications
H Vaisocherová, E Brynda, J Homola
Analytical and bioanalytical chemistry 407, 3927-3953, 2015
1662015
The hydrolysis of cationic polycarboxybetaine esters to zwitterionic polycarboxybetaines with controlled properties
Z Zhang, G Cheng, LR Carr, H Vaisocherová, S Chen, S Jiang
Biomaterials 29 (36), 4719-4725, 2008
1322008
Surface plasmon resonance biosensor for direct detection of antibody against Epstein-Barr virus
H Vaisocherová, K Mrkvová, M Piliarik, P Jinoch, M Šteinbachová, ...
Biosensors and Bioelectronics 22 (6), 1020-1026, 2007
1252007
Comparative study of SPR and ELISA methods based on analysis of CD166/ALCAM levels in cancer and control human sera
H Vaisocherová, VM Faca, AD Taylor, S Hanash, S Jiang
Biosensors and Bioelectronics 24 (7), 2143-2148, 2009
1152009
Surface plasmon resonance biosensors for detection of Alzheimer disease biomarker
K Hegnerová, M Bockova, H Vaisocherová, Z Krištofiková, J Říčný, ...
Sensors and Actuators B: Chemical 139 (1), 69-73, 2009
1042009
Rapid and sensitive detection of multiple microRNAs in cell lysate by low-fouling surface plasmon resonance biosensor
H Vaisocherová, H Šípová, I Víšová, M Bocková, T Špringer, ML Ermini, ...
Biosensors and Bioelectronics 70, 226-231, 2015
922015
Towards parallelized surface plasmon resonance sensor platform for sensitive detection of oligonucleotides
M Piliarik, H Vaisocherová, J Homola
Sensors and Actuators B: Chemical 121 (1), 187-193, 2007
912007
Functionalized ultra-low fouling carboxy-and hydroxy-functional surface platforms: functionalization capacity, biorecognition capability and resistance to fouling from …
H Vaisocherová, V Ševců, P Adam, B Špačková, K Hegnerová, ...
Biosensors and Bioelectronics 51, 150-157, 2014
902014
Shielding effect of monovalent and divalent cations on solid-phase DNA hybridization: surface plasmon resonance biosensor study
T Špringer, H Šípová, H Vaisocherová, J Štěpánek, J Homola
Nucleic acids research 38 (20), 7343-7351, 2010
872010
Effect of the immobilisation of DNA aptamers on the detection of thrombin by means of surface plasmon resonance
V Ostatná, H Vaisocherová, J Homola, T Hianik
Analytical and bioanalytical chemistry 391, 1861-1869, 2008
872008
Advanced biosensing using simultaneous excitation of short and long range surface plasmons
R Slavík, J Homola, H Vaisocherová
Measurement Science and Technology 17 (4), 932, 2006
732006
The system can't perform the operation now. Try again later.
Articles 1–20