Insufficient insulin administration to diabetic rats increases substrate utilization and maintains lactate production in the kidney C Laustsen, K Lipsø, JA Østergaard, R Nørregaard, A Flyvbjerg, ... Physiological reports 2 (12), e12233, 2014 | 46 | 2014 |
Large dose hyperpolarized water with dissolution-DNP at high magnetic field KW Lipsø, S Bowen, O Rybalko, JH Ardenkjær-Larsen Journal of Magnetic Resonance 274, 65-72, 2017 | 36 | 2017 |
Renal MR angiography and perfusion in the pig using hyperpolarized water K Wigh Lipsø, ESS Hansen, RS Tougaard, C Laustsen, ... Magnetic resonance in medicine 78 (3), 1131-1135, 2017 | 23 | 2017 |
Dissolution Dynamic Nuclear Polarization capability study with fluid path RM Malinowski, KW Lipsø, MH Lerche, JH Ardenkjær-Larsen Journal of Magnetic Resonance 272, 141-146, 2016 | 19 | 2016 |
Dynamic coronary MR angiography in a pig model with hyperpolarized water KW Lipsø, ESS Hansen, RS Tougaard, C Laustsen, JH Ardenkjær‐Larsen Magnetic Resonance in Medicine 80 (3), 1165-1169, 2018 | 17 | 2018 |
Measuring the effect of demagnetization in stacks of gadolinium plates using the magnetocaloric effect KW Lipsø, KK Nielsen, DV Christensen, CRH Bahl, K Engelbrecht, ... Journal of magnetism and magnetic materials 323 (23), 3027-3032, 2011 | 16 | 2011 |
Hyperpolarized 13C MR angiography K W Lipso, P Magnusson, J Henrik Ardenkjaer-Larsen Current Pharmaceutical Design 22 (1), 90-95, 2016 | 7 | 2016 |
High intrarenal lactate production inhibits the renal pseudohypoxic response to acutely induced hypoxia in diabetes C Laustsen, K Lipsø, JA Østergaard, PM Nielsen, LB Bertelsen, ... Tomography 5 (2), 239-247, 2019 | 4 | 2019 |
Modeling of cell reactions and advection-diffusion processes in microfluidic biochips KW Lipsø Master’s thesis, Technical University of Denmark, 2012 | 1 | 2012 |
Hyperpolarized Water Perfusion in the Porcine Brain–a Pilot Study ESS Hansen, HKW Lipsø, RS Tougaard, C Laustsen, ... ISMRM 25th Annual Meeting & Exhibition, 2017 | | 2017 |
Oxygen metabolic competition in the lactic acidotic diabetic kidney: A point of no return? C Laustsen, K Lipsø, JA Østergaard, P Mose, A Flyvbjerg, M Pedersen, ... The FASEB Journal 30, 740.7-740.7, 2016 | | 2016 |
A novel MR contrast agent for angiography and perfusion: Hyperpolarized water HKW Lipsø Technical University of Denmark, Department of Electrical Engineering, 2016 | | 2016 |
Magnetic Resonance Angiography in the Pig using Hyperpolarized Water HKW Lipsø, S Bowen, C Laustsen, ESS Hansen, T Nørlinger, ... Hyperpolarized Magnetic Resonance: Joint 5th International DNP Symposium and …, 2015 | | 2015 |
Hyperpolarized 13C MRS reveals oxygen sensitive pseudo hypxia in the diabetic kidney C Laustsen, K Lipsoe, F Palm, JA Østergaard, R Nørregaard, A Flyvbjerg, ... | | 2014 |
Cerebral angiography in rats: comparison of 1h tof-mra, spio enhancement and hyperpolarized 13c bssfp HKW Lipsø, P Magnusson, LV Søgaard, JH Ardenkjær-Larsen ISMRM 21st Annual Meeting & Exhibition, 2013 | | 2013 |
Oxygen metabolic competition in the lactic acidotic diabetic kidney: A point of no return?-DTU Orbit (04/01/2019) C Laustsen, HKW Lipsø, JA Østergaard, PM Nielsen, A Flyvbjerg, ... | | |
Hyperpolarized Water Perfusion in the Porcine Brain–a Pilot Study-DTU Orbit (19/12/2018) E Søvsø Szocska Hansen, HKW Lipsø, RS Tougaard, C Laustsen | | |
Oxygen metabolic competition in the lactic acidotic diabetic kidney: A point of no return?-DTU Orbit (03/01/2019) C Laustsen, HKW Lipsø, JA Østergaard, PM Nielsen, A Flyvbjerg, ... | | |