Follow
Maria Cristina Dias Tavares
Maria Cristina Dias Tavares
Professor of Electrical Engineering, University of Campinas
Verified email at unicamp.br
Title
Cited by
Cited by
Year
Mode domain multiphase transmission line model-use in transient studies
MC Tavares, J Pissolato, CM Portela
IEEE Transactions on Power Delivery 14 (4), 1533-1544, 1999
1021999
Six-phase transmission line-propagation characteristics and new three-phase representation
CM Portela, MC Tavares
IEEE Transactions on Power Delivery 8 (3), 1470-1483, 1993
871993
Half-wave length line energization case test-proposition of a real test
MC Tavares, CM Portela
2008 International Conference on High Voltage Engineering and Application …, 2008
812008
Transmission system parameters optimization-sensitivity analysis of secondary arc current and recovery voltage
MC Tavares, CM Portela
IEEE Transactions on Power Delivery 19 (3), 1464-1471, 2004
672004
A new procedure to derive transmission-line parameters: Applications and restrictions
S Kurokawa, J Pissolato, MC Tavares, CM Portela, AJ Prado
IEEE transactions on power delivery 21 (1), 492-498, 2005
612005
Earth conductivity and permittivity data measurements: Influence in transmission line transient performance
CM Portela, JB Gertrudes, MC Tavares, J Pissolato
Electric power systems research 76 (11), 907-915, 2006
572006
Behavior of overhead transmission line parameters on the presence of ground wires
S Kurokawa, MC Tavares, CM Portela, AJ Prado
IEEE transactions on power delivery 20 (2), 1669-1676, 2005
572005
Implementation and performance evaluation of a reclosing method for shunt reactor-compensated transmission lines
P Mestas, MC Tavares, AM Gole
IEEE Transactions on Power Delivery 26 (2), 954-962, 2010
552010
Modeling, simulation and optimization of transmission lines. Applicability and limitations of some used procedures
C Portela, MC Tavares
IEEE Transmission and Distribution Latin America, 38, 2002
552002
Faulted phase selection for half-wavelength power transmission lines
RGF Espinoza, MC Tavares
IEEE Transactions on Power Delivery 33 (2), 992-1001, 2017
442017
Comparison between traditional single‐phase auto reclosing and adaptive technique based on harmonic content measurement
O Dias, MC Tavares
IET Generation, Transmission & Distribution 11 (4), 905-914, 2017
442017
Accurate representation of soil behaviour for transient studies
CM Portela, MC Tavares, J Pissolato Filho
IEE Proceedings-Generation, Transmission and Distribution 150 (6), 736-744, 2003
442003
Comparison of secondary arcs for reclosing applications
O Dias, F Magrin, MC Tavares
IEEE Transactions on Dielectrics and Electrical Insulation 24 (3), 1592-1599, 2017
422017
Methodology for optimizing the capacity and costs of overhead transmission lines by modifying their bundle geometry
JS Acosta, MC Tavares
Electric Power Systems Research 163, 668-677, 2018
382018
Quasi-modes multiphase transmission line model
MC Tavares, J Pissolato Filho, CM Portela
Electric Power Systems Research 49 (3), 159-167, 1999
361999
Voltage harmonic content of long artificially generated electrical arc in out-door experiment at 500 kV towers
MC Tavares, J Talaisys, A Camara
IEEE Transactions on Dielectrics and Electrical Insulation 21 (3), 1005-1014, 2014
302014
Adaptative single-phase autoreclosing based on secondary arc voltage harmonic signature
AA Montanari, MC Tavares, CM Portela
parameters 6, 7, 2009
302009
Transient analysis concerning capacitor bank switching in a distribution system
DV Coury, CJ Dos Santos, M Oleskovicz, MC Tavares
Electric Power Systems Research 65 (1), 13-21, 2003
302003
Technical and economic comparison between direct current and half‐wavelength transmission systems for very long distances
G Samorodov, S Kandakov, S Zilberman, T Krasilnikova, MC Tavares, ...
IET Generation, Transmission & Distribution 11 (11), 2871-2878, 2017
292017
Modeling a power transformer for investigation of digital protection schemes
DV Coury, PG Campos, MC Tavares
8th International Conference on Harmonics and Quality of Power. Proceedings …, 1998
291998
The system can't perform the operation now. Try again later.
Articles 1–20