Analytical chemistry in a drop. Solvent extraction in a microdrop H Liu, PK Dasgupta Analytical Chemistry 68 (11), 1817-1821, 1996 | 972 | 1996 |
Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry B Zhang, H Liu, BL Karger, F Foret Analytical Chemistry 71 (15), 3258-3264, 1999 | 437 | 1999 |
Development of multichannel devices with an array of electrospray tips for high-throughput mass spectrometry H Liu, C Felten, Q Xue, B Zhang, P Jedrzejewski, BL Karger, F Foret Analytical Chemistry 72 (14), 3303-3310, 2000 | 265 | 2000 |
Light emitting diode based flow-through optical absorption detectors PK Dasgupta, HS Bellamy, H Liu, JL Lopez, EL Loree, K Morris, ... Talanta 40 (1), 53-74, 1993 | 155 | 1993 |
A renewable liquid droplet as a sampler and a windowless optical cell. Automated sensor for gaseous chlorine H Liu, PK Dasgupta Analytical Chemistry 67 (23), 4221-4228, 1995 | 115 | 1995 |
Analytical chemistry in a drop H Liu, PK Dasgupta TrAC Trends in Analytical Chemistry 15 (9), 468-475, 1996 | 95 | 1996 |
Fluorometric fiber optic drop sensor for atmospheric hydrogen sulfide AA Cardoso, H Liu, PK Dasgupta Talanta 44 (6), 1099-1106, 1997 | 74 | 1997 |
Dual-wavelength photometry with light emitting diodes. Compensation of refractive index and turbidity effects in flow-injection analysis H Liu, PK Dasgupta Analytica chimica acta 289 (3), 347-353, 1994 | 72 | 1994 |
A liquid drop: A windowless optical cell and a reactor without walls for flow injection analysis H Liu, PK Dasgupta Analytica chimica acta 326 (1-3), 13-22, 1996 | 68 | 1996 |
Computer-interfaced bipolar pulse conductivity detector for capillary systems S Kar, PK Dasgupta, H Liu, H Hwang Analytical Chemistry 66 (15), 2537-2543, 1994 | 68 | 1994 |
Flow-injection extraction without phase separation based on dual-wavelength spectrophotometry H Liu, PK Dasgupta Analytica chimica acta 288 (3), 237-245, 1994 | 60 | 1994 |
Expanding the linear dynamic range for multiple reaction monitoring in quantitative liquid chromatography–tandem mass spectrometry utilizing natural isotopologue transitions H Liu, L Lam, PK Dasgupta Talanta 87, 307-310, 2011 | 48 | 2011 |
High performance optical absorbance detectors based on low noise switched integrators H Liu, PK Dasgupta, HJ Zheng Talanta 40 (9), 1331-1338, 1993 | 48 | 1993 |
A microfabricated hybrid device for DNA sequencing S Liu, J Zhang, H Ren, J Zheng, H Liu Procedings of the uTAS 2001 Symposium, 99-100, 2001 | 47 | 2001 |
A dual-wavelength light-emitting diode based detector for flow-injection analysis process analysers J Huang, H Liu, A Tan, J Xu, X Zhao Talanta 39 (6), 589-592, 1992 | 43 | 1992 |
Black box linearization for greater linear dynamic range: the effect of power transforms on the representation of data PK Dasgupta, Y Chen, CA Serrano, G Guiochon, H Liu, JN Fairchild, ... Analytical chemistry 82 (24), 10143-10150, 2010 | 34 | 2010 |
A liquid drop: what is it good for? H Liu, PK Dasgupta Microchemical journal 57 (2), 127-136, 1997 | 29 | 1997 |
A falling drop for sample injection in capillary zone electrophoresis H Liu, PK Dasgupta Analytical Chemistry 69 (6), 1211-1216, 1997 | 29 | 1997 |
Method of improving stability of sweet enhancer and composition containing stabilized sweet enhancer C Tachdjian, DS Karanewsky, XQ Tang, H Liu US Patent 9,000,054, 2015 | 27 | 2015 |
Expanding the linear dynamic range for quantitative liquid chromatography-high resolution mass spectrometry utilizing natural isotopologue signals H Liu, L Lam, L Yan, B Chi, PK Dasgupta Analytica chimica acta 850, 65-70, 2014 | 23 | 2014 |